If your gas furnace pilot light is not staying lit, it can be a frustrating and potentially dangerous issue. In this comprehensive analysis, we’ll explore the common causes, troubleshooting steps, and necessary tools and costs to help you get your furnace back up and running safely.
What Causes a Gas Furnace Pilot Light to Not Stay Lit?
1. Thermocouple Failure
The thermocouple is a critical safety component that detects the pilot light flame and shuts off the gas supply if the flame is not present. Issues can arise if the thermocouple is dirty, broken, or not properly aligned.
Troubleshooting Steps:
– Check the Alignment: Ensure the thermocouple is correctly positioned to sense the pilot light flame.
– Clean the Thermocouple: Use a wire brush to clean soot and debris.
– Check the Resistance: Use a multimeter to measure the thermocouple’s resistance, which should be around 30-40 ohms. If it’s outside this range, it may need replacement.
Tools Required: Multimeter, wire brush
Estimated Time: 15-30 minutes
Cost: Replacement thermocouple can cost between $20-$50
2. Dirty Pilot Orifice
A clogged pilot orifice can weaken the pilot light flame, causing the thermocouple to shut off the gas supply.
Troubleshooting Steps:
– Inspect and Clean: Use compressed air or a wire brush to clean the orifice. However, this is best done by a professional to avoid damaging the components.
Tools Required: Compressed air, wire brush (professional use recommended)
Estimated Time: 30-60 minutes (professional service)
Cost: Professional cleaning service can cost between $50-$150
3. Gas Supply Issues
Problems with the gas valve or regulator can prevent the pilot light from staying lit.
Troubleshooting Steps:
– Check the Gas Valve: Ensure the gas valve is turned to the “On” position. If the valve is faulty, it may need replacement.
– Check the Gas Regulator: Verify that the gas regulator is functioning correctly and providing the proper pressure (typically 3.5 inches of water column for natural gas).
Tools Required: Adjustable wrench
Estimated Time: 15-30 minutes
Cost: Replacement gas valve can cost between $50-$200, and a gas regulator can cost between $100-$300
4. Venting Problems
Blockages in the venting system can cause the pilot light to go out due to improper combustion.
Troubleshooting Steps:
– Inspect the Venting System: Check for blockages or damage in the venting system. Use a vacuum to clean out any debris.
Tools Required: Vacuum
Estimated Time: 30-60 minutes
Cost: No cost if done by the homeowner, but professional service can range from $50-$150
Step-by-Step Troubleshooting Schedule
- Initial Check (10 minutes)
- Ensure the thermostat is set to “HEAT” and “ON”.
-
Check the circuit breaker and reset if necessary.
-
Thermocouple Check (15-30 minutes)
- Inspect the thermocouple’s alignment and cleanliness.
-
Measure the thermocouple’s resistance using a multimeter.
-
Pilot Orifice Inspection (30-60 minutes)
- Inspect the pilot orifice for dirt and debris.
-
Clean the orifice if possible, or schedule a professional cleaning.
-
Gas Supply Check (15-30 minutes)
- Verify the gas valve is in the “On” position.
-
Check the gas regulator for proper pressure.
-
Venting System Inspection (30-60 minutes)
- Inspect the venting system for blockages.
- Clean out any debris using a vacuum.
Products and Replacement Parts
- Thermocouple: Available at hardware stores or online, costing between $20-$50.
- Gas Valve: Available at hardware stores or online, costing between $50-$200.
- Gas Regulator: Available at hardware stores or online, costing between $100-$300.
References
- Four Seasons Heating and Air: “Why Won’t My Furnace Pilot Light Stay Lit?”
- Air Experts Heating & Cooling: “What To Do If Your Pilot Light Isn’t Working”
- Express Plumbing Idaho: “8 Gas Furnace Pilot Light Troubleshooting Tips”.